MelPump

MelPump Compatibility Clivet WiSAN-YME 1 S

CL

Clivet WiSAN-YME 1 S

Select an integration method below to see supported data points and features.

Monitored data points

Parameters available in the MelPump dashboard and reports. The "Control" column shows if you can also change the value from the app.

Parameter Description Monitor Control
Flow Temp Boiler Water temperature leaving the backup boiler check_circle remove
COP Efficiency ratio - heat output divided by electricity input check_circle remove
Compressor Frequency Speed of the compressor in Hz, higher values mean more heating or cooling power check_circle remove
Compressor Frequency Speed of the compressor in Hz, higher values mean more heating or cooling power check_circle remove
Defrost Mode Indicates when the outdoor unit is melting ice buildup check_circle remove
Delta Temp Difference between the water leaving and returning to the heat pump, used to show how much heat is being transferred check_circle remove
Operation Mode Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. check_circle tune
Tank Water Temp Current temperature of the domestic hot water stored in the tank check_circle remove
Target Tank Water Temp Desired domestic hot water tank temperature check_circle tune
Input Power Estimated electrical power being consumed check_circle remove
Output Power Estimated heat energy being produced check_circle remove
Lev A Electronic expansion valve opening position check_circle remove
Error Code Diagnostic code shown when there is a problem check_circle remove
Has Error Indicates if the system has an active error check_circle remove
Flow Rate Amount of water flowing through the system in litres per minute check_circle remove
Flow Rate Amount of water flowing through the system in litres per minute check_circle remove
Force Hot Water Forces immediate hot water heating regardless of schedule check_circle tune
Force Hot Water Forces immediate hot water heating regardless of schedule check_circle tune
Holiday mode Reduced operation mode to save energy during vacations check_circle remove
Holiday mode Reduced operation mode to save energy during vacations check_circle remove
Indoor Temp #1 Current air temperature in rooms served by heating zone #1 check_circle remove
Thermostat Temp #1 Desired room temperature set for heating zone #1 check_circle tune
Return Temp Water temperature returning to the heat pump from the heating system check_circle remove
Operation Mode Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. check_circle tune
Operation Mode Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. check_circle tune
Outdoor Temp Current outside air temperature measured near the heat pump check_circle remove
Fan 1 RPM Speed of the first outdoor unit fan check_circle remove
Flow Temp Water temperature leaving the heat pump and going into the heating system check_circle remove
Target Temp #1 Target water temperature for the heating circuit in zone #1 check_circle remove
Liquid Line Temp Temperature of the liquid refrigerant flowing through the heat pump's cooling circuit check_circle remove
Power Whether the heat pump is turned on or off check_circle tune
Flow Temp Water temperature leaving the heat pump and going into the heating system check_circle remove
Water Pump 1 Status Shows if the water circulation pump is running check_circle remove
Operation Mode #1 Operating mode for heating zone #1. In most heat pumps this is either constant flow or compensation curve mode, but some models may support advanced modes like auto-adaptation. check_circle tune
Operation Mode #2 Operating mode for heating zone #2. In most heat pumps this is either constant flow or compensation curve mode, but some models may support advanced modes like auto-adaptation. check_circle tune
Prohibit Heating Hot Water When enabled, prevents hot water heating check_circle tune
Eco Hot Water Energy-saving mode that heats water more slowly using lower flow temperatures for better efficiency check_circle tune

App-level features

Automation and optimization modes that MelPump unlocks for this integration.

bolt Summer Eco mode
bolt Smart Energy (dynamic pricing)
bolt Solar Mode - Hot Water
bolt Solar Mode - Zone Heating
bolt Night mode
bolt Advanced Scheduler
bolt Push and Email Notifications
bolt Energy Estimation

Connect your Clivet WiSAN-YME 1 S today