Panasonic Aquarea
Select an integration method below to see supported data points and features.
Monitored data points
Parameters available in the MelPump dashboard and reports. The "Control" column shows if you can also change the value from the app.
| Parameter | Description | Monitor | Control |
|---|---|---|---|
| COP | Efficiency ratio - heat output divided by electricity input | check_circle | remove |
| Compressor Frequency | Speed of the compressor in Hz, higher values mean more heating or cooling power | check_circle | remove |
| Delta Temp | Difference between the water leaving and returning to the heat pump, used to show how much heat is being transferred | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | remove |
| Tank Water Temp | Current temperature of the domestic hot water stored in the tank | check_circle | remove |
| Target Tank Water Temp | Desired domestic hot water tank temperature | check_circle | tune |
| Input Power | Estimated electrical power being consumed | check_circle | remove |
| Output Power | Estimated heat energy being produced | check_circle | remove |
| Error Code | Diagnostic code shown when there is a problem | check_circle | remove |
| Has Error | Indicates if the system has an active error | check_circle | remove |
| Flow Rate | Amount of water flowing through the system in litres per minute | check_circle | remove |
| Flow Rate | Amount of water flowing through the system in litres per minute | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | remove |
| Indoor Temp #1 | Current air temperature in rooms served by heating zone #1 | check_circle | remove |
| Thermostat Temp #1 | Desired room temperature set for heating zone #1 | check_circle | tune |
| Return Temp | Water temperature returning to the heat pump from the heating system | check_circle | remove |
| Max Tank Water Temperature | Maximum allowed hot water tank temperature setting | check_circle | remove |
| Operation Mode | Current mode: heating, cooling, or hot water production. May also show other modes like antifreeze or legionella. | check_circle | remove |
| Outdoor Temp | Current outside air temperature measured near the heat pump | check_circle | remove |
| Flow Temp | Water temperature leaving the heat pump and going into the heating system | check_circle | remove |
| Power | Whether the heat pump is turned on or off | check_circle | tune |
| Operation Mode #1 | Operating mode for heating zone #1. In most heat pumps this is either constant flow or compensation curve mode, but some models may support advanced modes like auto-adaptation. | check_circle | tune |
| Indoor Temp #2 | Current air temperature in rooms served by heating zone #2 | check_circle | remove |
| Thermostat Temp #2 | Desired room temperature set for heating zone #2 | check_circle | remove |
| Prohibit Heating Zone #1 | When enabled, prevents heating in zone #1 | check_circle | tune |
| Operation Mode #1 | Operating mode for heating zone #1. In most heat pumps this is either constant flow or compensation curve mode, but some models may support advanced modes like auto-adaptation. | check_circle | tune |
App-level features
Automation and optimization modes that MelPump unlocks for this integration.
bolt
Summer Eco mode
bolt
Solar Mode - Hot Water
bolt
Night mode
bolt
Advanced Scheduler
bolt
Push and Email Notifications
bolt
Energy Estimation